Date modified: 20.11.2026
Technical support: tsup@elecard.ru

2. User Guide

Elecard CodecWorks Mux Description

Elecard CodecWorks Mux is a professional solution designed for real-time multimedia multiplexing, operating on a broad spectrum of hardware.

Activation

To activate the product, receive the license from the License Server installed in the same subnet as CodecWorks Mux.

License Server is linked to a specific HWKey (hardware key). To receive your HWkey, use a dedicated app to obtain the ID specific to your device—the installation package will later be bound to said device. To receive the app, contact the technical support or your project’s coordinator.

Licensing and Technical Support

Elecard CodecWorks Mux is available as a demo version or a registered product. By installing, copying, or otherwise using the software product or any updates, you agree to be bound by the terms of the Elecard End-User License Agreement (EULA). This EULA is a legal agreement between you (either an individual or a single entity) and Elecard for the Elecard software product(s) accompanying this EULA, which include(s) computer software and may include online or electronic documentation, associated media, and printed materials.

For sales and licensing information, contact the Elecard Sales Department
For technical support, contact the Elecard Technical Support Team

License Server

License Server is a license management service for the CodecWorks product line-up linked to a specific HWkey as well as specific IP address or domain name for issuing certificates. It consists of the server and the client:

  • The server part must be installed in the same subnet as the purchased software. After detecting the server in the subnet, the software will request permission to operate;

  • The client part is represented by a web interface, available after the server’s installation.

After logging in you will be redirected to the License Server homepage. To log in, use the following default account credentials:

Username — admin Password — elecard

In the top part of the web interface you can look up the required license’s name as well as configure the displayed list using the following filters:

  • Restrictions — number of limitations and thresholds applied to the product as well as the features available in the license;

  • Features — number of features available in the license;

  • Allocated parts — number of servers that are part of the license.

  • Expiration date — license’s expiration date.

The table below shows info on each available license. The displayed info is the same as what can be configured in the filters. To learn more about a specific product’s license, click on its name in the Client name column.

The table to the right shows info on License Server itself:

  • Status — the License Server current status;

  • License count — the number of licenses linked to License Server;

  • Allocated parts count — total number of allocated parts that are part of available licenses;

  • Server version — version of the server part of License Server;

  • Web client version — version of the client part, dependent on the server part;

  • Operating system — operating system of the device where the server part of License Server is deployed in;

  • Start time — date and time of the server’s launch;

  • Server time — current date and time in UTC;

  • Working time — total operation time of License Server.

Product-Specific License Info

Click on the license’s name in the Client name column to be redirected to the page containing in-depth descriptions of the license itself, its allocated parts, etc. The page consists of 3 tabs:

Overview

Product license summary broken down into the following sections:

  1. General information:

  • Client name — license name;

  • Status — license status;

  • Valid until — license expiration date and time;

  • Part lifetime — specified lifetime, during which allocated parts will continue operating in case of failure of License Server. It is during this period that the user can restore License Server’s operation without the allocated parts shutting down;

  • Allocated parts — number of servers that are part of the license.

  1. Restrictions overview:

  • Total restrictions — number of restrictions applied to the license;

  • Countable limits — restrictions created around digit-based parameters (such as the number of software encoders or decoders);

  • Thresholds — restrictions on the max specified threshold values (such as the maximum bitrate for video encoders);

  • Features — restrictions on product-specific functionality (such as subtitle recognition in various video transmission protocols).

  1. Features overview: list of product-specific features (such as subtitle recognition in various video transmission protocols).

  2. Allocated parts count: summary graph showing the state of all allocated parts relevant to the license. The X axis shows the number of allocated parts, the Y axis shows the timeline.

  3. Allocated parts — number of servers that are part of the license. Click on a block to browse info specific to this part.

Restrictions

Page containing info on the specified limits, thresholds, and available features that are specific to the license. Click on an element for a more in-depth description containing the summary, name, ID, as well the taken up resources and expiration date. Among the available elements are:

  • Countable limits — restrictions created around digit-based parameters (such as the number of software encoders or decoders);

  • Thresholds — restrictions on the max specified threshold values (such as the maximum bitrate for video encoders);

  • Features — restrictions on product-specific functionality (such as subtitle recognition in various video transmission protocols).

Note

The only limit applicable to CodecWorks Mux is the maximum bitrate for video encoders; no specific features are included in the license for this product.

JSON

Info regarding the restrictions and allocated parts represented as a JSON schema. The following is an example of a JSON schema containing the maximum bitrate restriction as well as 6 allocated parts:

{
  "restrictions": {
    "max_mux_bitrate": {
      "type": "Countable",
      "value": 1000000000
    }
  },
  "allocated_parts": {
    "0avXIT2gIOGOjZ7v": {
      "part_id": "0avXIT2gIOGOjZ7v",
      "expired_time": "2026-11-13T15:08:17.525049877+07:00",
      "local_expired_time": 1308756,
      "restrictions": {
        "max_mux_bitrate": {
          "type": "Countable",
          "value": 1
        }
      },
      "label": "Codec-Works-test-30:Mux|Common"
    },
    "6tBATrAi106Fcpad": {
      "part_id": "6tBATrAi106Fcpad",
      "expired_time": "2026-11-13T15:08:13.729171745+07:00",
      "local_expired_time": 1308752,
      "restrictions": {
        "max_mux_bitrate": {
          "type": "Countable",
          "value": 1
        }
      },
      "label": "Codec-Works-test-30:Probe|Common"
    },
    "HfP6i4AUjz8k0tsu": {
      "part_id": "HfP6i4AUjz8k0tsu",
      "expired_time": "2026-11-13T15:08:22.61548323+07:00",
      "local_expired_time": 1308761,
      "restrictions": {
        "max_mux_bitrate": {
          "type": "Countable",
          "value": 10603645
        }
      },
      "label": "Codec-Works-test-30:Mux1|Common:metered"
    },
    "KmtyPiV1l2iEQuaJ": {
      "part_id": "KmtyPiV1l2iEQuaJ",
      "expired_time": "2026-11-13T15:08:15.234218339+07:00",
      "local_expired_time": 1308754,
      "restrictions": {
        "max_mux_bitrate": {
          "type": "Countable",
          "value": 1
        }
      },
      "label": "Codec-Works-test-30:Mux1|Common"
    },
    "Vu9kiOPfHJy3MCsu": {
      "part_id": "Vu9kiOPfHJy3MCsu",
      "expired_time": "2026-11-13T15:08:23.353722581+07:00",
      "local_expired_time": 1308762,
      "restrictions": {
        "max_mux_bitrate": {
          "type": "Countable",
          "value": 1
        }
      },
      "label": "Codec-Works-test-30:Probe1|Common"
    },
    "kaUEnHn9FylQhwp8": {
      "part_id": "kaUEnHn9FylQhwp8",
      "expired_time": "2026-11-13T15:08:17.815054091+07:00",
      "local_expired_time": 1308756,
      "restrictions": {
        "max_mux_bitrate": {
          "type": "Countable",
          "value": 94475640
        }
      },
      "label": "Codec-Works-test-30:Mux|Common:metered"
    }
  },
  "expired_time": "2027-06-09T08:44:20Z",
  "part_timeout": 60000,
  "total": {
    "restrictions": 1,
    "countable": 1,
    "allowing": 0,
    "max_treshold": 0,
    "allocated_parts": 6
  },
  "client_name": "Elecard Test Muxer"
}

Allocated Parts

When in the Overview tab, you can click on any block available in the Allocated parts section and move to a page containing info on a specific allocated part. The displayed info is similar to the summary on all allocated parts except for the following:

  1. On the Y axis, the Remaining part lifetime graph shows the specified time limit during which the allocated part will continue operating in case License Server runs into a failure.

  2. The Restrictions section shows this specific part’s limits and features compared against the entire license’s restrictions.

System Requirements

To run Elecard CodecWorks Mux, your system must meet these minimum requirements:

  • CPU: 4 cores or more, 2.0 GHz

  • SSD/HDD: 256 GB or more

  • RAM: 16 GB or more

    Tip

    Recommendations on RAM module configuration

    To achieve maximum performance when working with video streams, use the following formula to figure out the optimal number of RAM modules you need: \([\text{Memory channels per CPU}] \times [\text{Number of CPUs}]\)

    How it works: The CPU memory controller accesses all channels simultaneously. When at least one module is installed in each channel of each processor, the system runs at maximum speed. If there are fewer modules than channels, some lanes remain idle, reducing overall bandwidth.
    Example: For a platform with 2 CPUs (8 channels each), it is optimal to install 16 identical modules (for example, 16 × 16 GB instead of 4 × 64 GB).
  • Linux Ubuntu Desktop/Server 22.04/24.04

    Tip

    Recommendations on OS network stack configuration

    When working with high-bitrate video streams (especially when transmitting over UDP/RTP/SRT/MPEG-TS), the default size of Linux kernel network buffers may be insufficient. Short traffic bursts or delays in packet processing can cause buffer overflow, leading to packet drops and resulting in corrupted video or stream desynchronization.

    To prevent packet loss, it is recommended to increase the maximum receive and transmit buffer sizes at the operating system level.

    Quick setup:

    Run the following commands in the terminal with sudo privileges:

    echo -e "\nnet.core.rmem_max=4194304\nnet.core.wmem_max=4194304" | sudo tee -a /etc/sysctl.conf
    sudo sysctl -p
    

    What these commands and parameters do:

    • echo -e "..." | sudo tee -a /etc/sysctl.conf — adds the parameters to the end of the /etc/sysctl.conf config file so the settings persist after a server reboot.

    • net.core.rmem_max=4194304 — increases the receive memory for network sockets to 4 MB. This lets the kernel temporarily queue more incoming packets while the application catches up.

    • net.core.wmem_max=4194304 — increases the write memory to 4 MB. This smooths out micro-delays during intensive output of multiplexed streams to the network.

    • sudo sysctl -p — reads the updated /etc/sysctl.conf file and immediately applies the new limits to the running OS kernel without requiring a system reboot.

Outbound traffic:

  1. 1535/TCP (required), 53700/TCP (optional) — used for communication between CodecWorks Mux services over the network.

  2. 1545/UDP (required) — used to discover other CodecWorks Mux services in the network.

  3. 8118/HTTP/HTTPS (required, default) — used for communication with the browser as well as for downloading logs and task configurations.

  4. 162/UDP (default) — used for sending SNMP messages. The port can be configured on the Service Options ➝ SNMP Settings page.

Installation

Follow the installation procedure described below:

Ubuntu

Before installation, we recommend to run the following commands:

sudo apt update
sudo apt upgrade

To install all packages at once, run the installer:

sudo apt install ./Elecard-CodecWorks Mux*.deb
The software will be installed to /usr/bin/Elecard/Mux
The created schemas will be saved to /etc/Elecard/Mux

Note

To ensure issue-free installation, Internet access is required to download dependencies. However, our technical support team can prepare a standalone package for you in case there is no direct access to the Internet.

Uninstallation

To remove Elecard CodecWorks Mux from your computer, follow the steps below:

Ubuntu

Run the following command:

sudo apt remove elecard-CodecWorks Mux*

Features

CodecWorks Mux provides the following functionality:

  • Multiplexing and stream generation:

    • generation of SPTS and MPTS output transport streams with constant (CBR) or variable (VBR) bitrate, including null-packet stuffing;

    • demultiplexing of incoming streams with the functionality to select individual programs (services) and elementary streams for subsequent assembly into an MPTS;

  • PID and PSI/SI table management:

    • processing (generation, editing, and pass-through) of mandatory and optional PSI/SI service tables (PAT, PMT, SDT, NIT, EIT, CAT, TDT/TOT):

      • EIT — pass-through only; editing is not supported;

      • CAT — pass-through only (encryption to be added in future releases).

    • PID remapping to prevent conflicts when merging multiple input streams;

    • filtering (removal) of unused or redundant PIDs and service data from the input stream;

    • editing of service metadata (channel names, providers, network ID, transport stream ID, service ID).

  • Synchronization and integrity control:

    • PCR (program clock reference) correction during remultiplexing to eliminate jitter and ensure smooth decoding;

    • monitoring of input and output streams for TR 101 290 standard errors (loss of synchronization, continuity counter errors, missing tables and PIDs).

  • Fault tolerance and management:

    • input stream redundancy with automatic failover to a backup source upon signal loss, CC errors, or missing configured PIDs;

    • fast server redundancy mechanisms based on 1+1, N+1, and N+M schemes.

Product Structure Description and Module Purpose

One operating system may contain only one multiplexing server that comprises the following modules:

  • Operating console — software designed to create (start) a multiplexing encoding schema. It receives and processes control commands from the manager (via an intermediary layer, i.e. CodecWorks Mux dispatcher), as well as controlling license restrictions. Depending on the number of licenses purchased, one or more consoles are started per server. An encoding console is represented by a task in the web interface.

  • Dispatcher — software (a console or a system service, depending on the user’s choice) that monitors encoding consoles, their initial startup, emergency restarts, communication with other devices on the network. It also obtains the server load statistics. One channel manager is run on one server.

  • Watcher — software (a console or a system service, depending on the user’s choice) that monitors the dispatcher operation and its emergency restart. Watcher, dispatcher, encoding consoles can be started as a system service or console applications, depending on the user’s choice.

Web Interface

Creating Multiplexing Services

Note

Currently, only the UDP protocol is implemented, meaning that only multicast streams can be received. Other protocols will be added in the future. To work with other protocols, use Elecard CodecWorks Gateway: it converts incoming traffic into a UDP stream without altering the transport stream (TS) structure and forwards it to the multiplexer.

The main page is divided into 4 columns, each representing a stage of creating a multiplexing schema:

Physical inputs

Automatically displays the system’s network interfaces that can be used to receive multicast streams. Each network interface can be assigned a list of multicast addresses for receiving streams.

To manually add a multicast address, hover over the required network interface → click on ⋮ → PlusIcon Add Input → configure one or more URIs (IP address + port) → confirm the addition. You can click on TemplateCopyIcon to copy the address and port, while clicking on TrashIcon will delete the added address.

Logical inputs

Displays the multicast streams received from the first column and lets you work with them at the transport level. Each stream within the column is a dropdown list, the sorting of information within depends on the selected display type. The column header has the following control elements available for interaction:

  • restartButton Update logical inputs — refreshes the list in case there are new streams in the Physical inputs column;

    • When a new input (multicast address) is added, the Logical inputs list will be refreshed automatically.

    • When the stream structure changes during operation, the system detects the changes and displays an exclamation mark on the button icon. Click it to apply the current configuration.

      Note

      Automatic refresh on structure change of active streams is intentionally disabled to prevent the current settings overwriting without the user’s confirmation.

  • configButton Default redundancy settings — configures the redundancy mode as well as the threshold values, upon reaching which the system will switch over to the backup source;

  • Color indicators point out the current schema status:

    • 🔴 — service stopped,

    • 🟡 — service is starting,

    • 🟢 — service is running.

  • ShowProgramsIcon Show as programs — sorts information by programs included in the stream. Clicking on a program will display information related to it: video and audio codec, teletext, service tables, etc.;

  • ShowTablesIcon Show as tables — sorts information by service tables—PAT, PMT, NIT, SDT, TDT, TOT, EIT—included in the stream. Clicking on a table will partially display its contents.

Each parent entity has nested elements inside—clicking on it will expand the contents: programs, tables, etc. To interact with an element, hover the cursor over it → click the ⋮ icon. The available features may be element-specific:

  • ⋮ → editUser Properties — view the parameters of a program, program component, or service table.

  • ⋮ → Redundancy → PlusIcon Add Source — adds a backup source for a specific stream. Select from the available sources the one you want to specify as the backup (for a source to appear in the list, first it has to be recognized in the Physical inputs column);

  • ⋮ → Drop to — moves the element to the next stage of the multiplexing schema. By moving a stream or part of a stream to the Logical outputs column, you can either create a new output or add to an existing output;

The in-column rows may also display warning/error-type notifications if a corresponding event has taken place.

Logical outputs

Displays the user-configured streams. By moving a stream or part of a stream to the Logical outputs column, you can either create a new output or add to an existing output. The parameters available in the Logical inputs column for viewing only can now be configured. To generate an output stream:

  • drag and drop an entire TS, a specific program, table, or PID from Logical inputs to Logical outputs,

  • or, while in the Logical inputs column, click ⋮ → Drop to, then choose the destination.

The column follows the logic of the previous stage except for the following functions:

  • PlusIcon Add logical output — lets you create an empty template that can be either filled with elements from the Logical inputs column or configured manually by hovering the cursor over the desired output → clicking on ⋮ → then on editUser Edit.

  • QuickFix Исправить — automatically resolves duplicate PID conflicts by assigning them free unique numbers and linking them to the required sections of the PSI/SI tables.

  • Rate Control — enables the user to manage the bitrate using the following settings:

    • Bitrate bit/s — the value in bits per second,

    • PCR_policy — the policy for modifying the program reference clock:

      • fix_interval — modify the PCR value and the packet where the PCR label is located,

      • fix_value — modify the PCR value,

      • none — leave the PCR as is.

      Warning

      In some cases, an incorrectly selected PCR modification metric may cause the PCR accuracy error.

    • PCR_interval — the interval in milliseconds between PCR packets (required for fix_interval). The default value is 25

    • Mode — packet send mode according to the system clock. Two modes are implemented:

      • none — packets are sent as they are delivered from the multiplexing part. In this case, packets are sent infrequently and in large bursts, which increases IAT and increases the probability of packet loss in the network,

      • simple — packets are sent more evenly, in accordance with the system clock.

  • Add table — lets you add a PMT, NIT, SDT, TDT, TOT table to the output and configure it from scratch.

Physical output

Automatically displays the system’s network interfaces that can be used for multicasting. Each network interface can be assigned a list of multicast addresses for stream delivery.

After you finish configuring the multiplexing schema, click Save and confirm the action. Without confirmation, the changes will not be saved.

Note

Elecard CodecWorks Mux does not support demultiplexing with PID parsing at the elementary stream level—the program operates exclusively at the transport packet (TS) level. For deeper demultiplexing, use Elecard CodecWorks. This approach offers both advantages and limitations:

  • Advantages: stream bitrates remain unchanged, since the system does not modify the structure of elementary streams.

  • Limitations: heterogeneous streams cannot be used for source reservation—all reserved streams must have an identical or similar structure.

Configuring Service Redundancy

Prior to configuring service redundancy, ensure that the following conditions are met:

  • The output stream is generated: the main service is already configured and being broadcast.

  • The backup source is free to use: the selected input stream was added to the system in advance but is not yet used in other multiplexes or services.

  • The stream structures are identical: the backup input stream fully matches the main one in terms of elementary stream composition, codecs, and PIDs.

Service Redundancy Modes

  • Manual — all switchover triggers are disabled, data is taken from the main (first) source, backup sources are ignored—neither received nor analyzed;

  • Automatic — automatic switchover to the highest-priority healthy backup source in case of issues on the currently-in-use main source;

  • Automatic with revert — the same as Automatic, but when a higher-priority source becomes healthy, a revert to it occurs regardless of whether there are issues on the currently-in-use main source.

Automatic Switchover Triggers

  • Bitrate underflow — across the entire transport stream or on a given PID, the bitrate—measured with respect to the system monotonic clock over a specified period—is below the minimum acceptable value. This trigger is configured via the following thresholds:

    • Period — the period in milliseconds defining the window over which the bitrate is measured.

    • Min bitrate — the minimum acceptable bitrate.

  • Input lost — across the entire transport stream or on a given PID, no data was present for a specified period. This trigger is configured via the following thresholds:

    • Period — the period in milliseconds, the absence of data during which activates the trigger.

  • CC errors — across the entire transport stream or on a given PID, at least X CC errors were recorded over a specified period. This trigger is configured via the following thresholds:

    • Period — the period in milliseconds defining the window over which the CC error counter is reset.

    • Count — the X number of errors recorded over the specified window.

  • PAT missing — the transport stream contains no data on the PAT PIDs for a specified period. This trigger is configured via the following thresholds:

    • Period — the period in milliseconds, the absence of data during which activates the trigger.

  • PMT missing — the transport stream contains no data on one or more PMT PIDs for a specified period. When enabled, PAT missing is also activated with the same thresholds, because without PAT it is impossible to determine the PMT. This trigger is configured via the following thresholds:

    • Period — the period in milliseconds during which the absence of data activates the trigger.

In case the Automatic with revert mode is enabled, an additional threshold will be added for all triggers:

  • Revert period — the time in milliseconds that must elapse after a trigger fires for a higher-priority source to qualify for a revert from a lower-priority one.

The Bitrate underflow, Input lost, and CC errors triggers can be set both for the entire transport stream and for individual PIDs. The PAT missing and PMT missing triggers can only be set for the entire transport stream.

_images/reserving_en.png

Configuring Server Redundancy

During operation, the backup server monitors the operation of the main server by periodically sending special signals to it and monitoring the receipt of responses. If there are no responses from the main server within a configurable period of time, the redundant server activates pre-configured encoding channels under its control. One redundant server can back up several working encoding servers (N+1 model). Also, multiple redundant servers can serve the same set of working servers (N+M model).

On the Home page, click the Redundancy button to open the redundancy page. It contains two columns:

  1. Main Servers — displays the names of main nodes to be backed up by redundant servers.

  2. Redundancy Servers — displays the names of redundant servers that will start in case of problems with main servers.

_images/redundancy_en.png

You can add one or multiple servers to the list by clicking the Add button. When the list is created, click the Save & Exit button. Server redundancy will be set up.

Note

A server on which the redundancy is configured is automatically included in the list of backup servers by default.

The redundant server will start if connection to the working CodecWorks Mux server is lost, i.e. when the dispatcher of the redundant server stops receiving responses from the dispatcher of the main server.

To switch to the redundant server manually, save the settings, then go to the redundancy page and select the server you want to bring out of operation from the main server list. Next, select a redundant server you want to bring in operation and click the transfer button.

If you click the Settings button on the Redundancy page, the Redundancy Settings window opens. In this window, you can configure the update of schemas on the redundant servers, the timeout for switching to the redundant server, and triggers that will be used for switching.

If the Update schemas on redundant servers by time option is enabled, the encoding schemas for redundant servers are automatically updated at the specified interval after the service start or beginning from the time specified by the user.

  • Number of failed requests is a number of consecutive failed requests within a TCP session. If the specified number of failed requests in a row is reached, a redundant server will start.

  • Request timeout (milliseconds) is the time between requests within a TCP session.

  • Failover timeout (milliseconds) is the calculated parameter defining the time between detecting a problem on a primary server and failing over to a redundant server.

Setting conditions for the server deactivation is a functionality that provides switching to the redundant server if one of the specified conditions is satisfied. Deactivation settings are applied to the current server and other servers in a redundancy group. There are the following conditions for deactivation of the server and subsequent switching to the redundant server:

  • CPU Usage — when this condition is chosen, the server will be deactivated if the specified CPU load threshold is exceeded within the set period.

The Action if conditions are met setting helps to configure the server behavior. If one or some conditions occur, a server can become a redundant server or go to a deactivated state.

Note

You can set a server as a redundant one only for 1+1 redundancy mode.

_images/Redundancy_Settings_en.png

Authentication and Managing User Roles

User authentication is used for differentiating access rights between various user groups. It also provides the possibility to identify the author of changes.

When launching CodecWorks Mux for the first time, use the default Administrator username and admin password to log in the web interface. To change the password or add a new account, go to the user permissions page.

To open the page, click the username in the right upper corner and select the Security Settings option from the menu. User groups are displayed in the left part of the window. They unite users with similar management rights.

The Administrators group is default and cannot be deleted. To create a new group, click the Add Group button, and specify the group name. To save changes, click the Apply button. When clicking a group, its settings will open in the right part of the page. In the Permissions tab, you can set permissions for actions with the CodecWorks Mux service and with encoding consoles. In the Users tab, the members of a chosen group are listed. In this tab, you can create users or change their passwords. To set a new password, select a user and click the editUser icon. Type in the old password, then fill in a new one and confirm it. Click Apply.

Configuring Server Settings

Go to the Settings → Service Settings → General tab to change Service name, Multicast address for finding CodecWorks Mux services within the network, the IP address used for this, and the IP address for the web interface.

Note

If you specify 0.0.0.0 as the network interface’s address, all network interfaces available to the system will be used.

Additionally, in this section you can pinpoint the maximum number of records in the event log and configure the task rebuild settings.

_images/General_en.png

Log and Rotation Settings

In the Logging tab, you can specify a folder for storing log files. Also, you can set logging levels for dispatcher, SNMP, access, and server events. When setting up consoles, you can specify the same logging level for all consoles or select a logging level for a certain console.

_images/Logging_en.png

In the Rotation tab, you can set a storage period and size for the following files:

  • Log files — system messages recorded into the log.

  • Crash dumps — process dumps created in various situations caused by incorrect operation.

  • Redundant copies of schemas — schemas saved as backups in the console /backup folder after each schema setting change so that these changes can be reversed.

You can also specify a rotation period for log files, which is measured from the moment the dispatcher starts. During rotation, the storage period and file size thresholds are checked. Files exceeding the thresholds will be deleted.

_images/Rotation_en.png

SNMP

Configuring the SNMP Agent

  1. Install the SNMP service:

    sudo apt-get install snmpd
    
  2. Specify a community and path to a CodecWorks Mux agent in the etc/snmp/snmpd.conf file:

    rwcommunity elecard
    rocommunity elecard
    
  3. Indicate a network interface address for the SNMP agent:

    agentaddress interface address,[::1]
    
  4. At the end of the file, add the path to the agent:

    dlmod libcwSnmpAgent /bin/Elecard/Mux/libcwSnmpAgent.so
    
  5. Restart the SNMP service:

    sudo systemctl restart snmpd.service
    

Note

If you reinstall Elecard CodecWorks Mux in the future, it is necessary to restart the SNMP service too.

Configuring SNMP notifications

CodecWorks Mux offers a possibility to send SNMP notifications to a desired trap point. They are used to report about problems related to an input stream, the start/stop of encoding schema work, a failover to a redundant source, etc.

The installed version of CodecWorks Mux contains two MIB files:

To configure SNMP notifications, go to the SNMP Settings section on the Service Settings page. The section contains the Community Settings and Severity Levels tabs. You can show or hide tabs using the SNMP Settings checkbox.

In the Community Settings tab, you can create a new SNMP community. To do this, click the Add button, enter the community name and click Ok. Then you need to add a destination address to which notifications for the selected community will be sent. First, click on the plus sign to the left of the created community name to show the list of destination addresses. Then, click the Add button, enter the address and port; click Ok. If you need to use multiple addresses, repeat adding destination addresses.

_images/SNMP1_en.png

The Severity Levels tab contains the Task States and Events sections. In these sections, you can set up sending notifications for task states and events that should be tracked:

Events

Events are mostly connected to a state change, e.g. a failover to a redundant server. The notifications of this type come only once. To enable tracking of a certain event, tick the checkbox to the left of its name and select the severity level of the event.

_images/SNMP2_en.png

Task States

Task States have both active and cleared levels indicating the beginning and the end of an event. The notifications are sent twice: when entering an event based on specific triggers and when exiting the event. To enable tracking a certain state, tick the checkbox to the left of its name and set the severity level in the Active Level and Cleared Level columns.

_images/SNMP3_en.png

Structure of SNMP Notifications

There are four types of SNMP trap notifications described in the ELECARD-CodecWorks Mux-MIB.mib file.

1. Notifications about changing the CodecWorks Mux service state (CodecWorks MuxState)

Such notifications characterize a certain state of the service and are sent twice: when an event occurs and when it ends. The notification contains the following fields:

  • status — a state status (active — if a state has occurred, cleared — if a state has ended);

  • trapName — a notification name;

  • trapMessage — a detailed notification description;

  • severityLevel — a notification severity level;

  • referenceNumber — a notification sequence number;

  • sequenceId — a parameter linking the start and end of a state (a state identifier is unique for each pair of notifications).

2. Notifications about an event that has occurred with the CodecWorks Mux service (CodecWorks MuxEvent)

These notifications are sent only once when a certain event occurs. Such a notification contains the following fields:

  • trapName — a notification name;

  • trapMessage — a detailed notification description;

  • severityLevel — a notification severity level;

  • referenceNumber — a notification sequence number.

3. Notifications about a change in the state of CodecWorks Mux encoding consoles (CodecWorks MuxChannelState)

Such notifications indicate a certain state of the encoding console and are sent twice: when an event occurs and when it ends. Such a notification contains the following fields:

  • status — a state status (active — if a state has occurred, cleared — if a state has ended);

  • trapName — a notification name;

  • trapMessage — a detailed notification description;

  • severityLevel — a notification severity level;

  • channelNumber — an encoding console number;

  • taskName — an encoding schema name;

  • referenceNumber — the sequence number of a notification;

  • sequenceId — a parameter linking the start and end of a state (a state identifier is unique for each pair of notifications).

4. Notifications about events of an encoding console (CodecWorks MuxChannelEvent)

These notifications are sent once a certain event happens. Such a notification contains the following fields:

  • trapName — a notification name;

  • trapMessage — a detailed notification description;

  • severityLevel — a notification severity level;

  • channelNumber — an encoding console number;

  • taskName — an encoding schema name;

  • referenceNumber — the sequence number of a notification.

Possible Values of Some Notification Fields

The severityLevel field can take the following values:

  • ok (1);

  • warning (2);

  • error (3);

  • major (4);

  • fatal (5).

The values of trapName and trapMessage fields are described in the table below.

trapName

trapMessage

Description

Backup server

Host <host:port> is down, backup started

Backup server start

Service start

Service started

Service start

Service stop

Service stopped. <reason>

Service disabling

Console stop

<reason>

Stop of encoding console

TS errors

Stream <stream number> - CC errors

Errors in transport stream

Setting Up Options

Options are presented as a table of service parameters that the user can utilize at their discretion. The user can use a set of existing options and also add their own.

Options can be added or configured via the web interface.

To add an option, click PlusIcon—a new row will appear in the table with the following columns:

  • Name — the name of the option. Enter your own name or select one of the existing entries.

  • Description — the option description.

  • Value — the option value, which can be an integer or a string.

    When selecting one of the existing options, the default value will be set automatically (if available).

To delete an option, click the deleteButton button.

Note

Existing options with the app prefix are service parameters of the application—such parameters can be interpreted by the application itself and affect its behavior. Avoid using this prefix when adding new entries: new app options may conflict with future versions of the application and unpredictably affect the service’s operation.

Click to expand the drop-down list with descriptions of the existing app options

app.LogDirectory

The directory where CodecWorks writes log files. By default, this is the log directory for the current application domain.

app.StartDelay

The total latency before consoles start in seconds. Prior to total latency, individual console latency is applied. Default value: 0 (no additional latency). A positive value sets the interval.

app.StatLogTime

The statistics write interval in seconds; app.Reserved2 selects CSV output. Default value: 0 (statistics logging disabled). A positive value sets the interval.

app.DumpLevel

Controls the creation and detail level of crash dumps. By default, the parameter not specified, and the built-in mode is used; on Windows, -1 disables dumps, and -2 creates a full memory dump.

app.IgnoreAutoRun

Prevents the graph from starting automatically, even if AutoRun is enabled in the channel configuration. By default, the parameter is not specified (mode disabled); 1 enables it, 0 disables it.

app.SoundAlertFile

The audio file for sound alerts. By default, the parameter is not specified; the component’s built-in behavior applies.

app.StartTimeout

The maximum graph start-up time in seconds, after which the console is restarted. Default value: 10.

app.SourceReservingRestart

Restarts the console when switching to a redundant source. In GStreamer, a restart is always used. By default, the parameter is not specified (mode disabled); 1 enables it, 0 disables it.

app.UseProxy

Enables the use of a proxy; the explicit proxy address is set by the app.Proxy parameter. By default, the parameter is not set (mode disabled); 1 enables it, 0 disables it.

app.Proxy

The explicit proxy address. If not set, the platform’s system proxy may be used. By default, the parameter is not set; the component’s built-in behavior applies.

app.ReservingPingTimeout

The maximum waiting time for a response from a reserved node to a ping request in milliseconds. Default value: 1000.

app.Channel.Graph.Load.Parameters.SkipDefault

Skips applying parameters the values of which match the default values when loading the graph. By default, the parameter is not set (mode disabled); 1 enables it, 0 disables it.

app.Channel.Terminate.Dump

Creates a crash dump on forced termination of the console. By default, the parameter is not set (mode disabled); 1 enables it, 0 disables it.

app.Dispatcher.Terminate.Dump

Creates a crash dump on forced termination of the dispatcher. By default, the parameter is not set (mode disabled); 1 enables it, 0 disables it.

app.Dispatcher.StopProcess.Timeout

The time given to a child process to stop before it is forced to terminate by the dispatcher in seconds. Default value: 20.

app.Login.Session.MaxAge

The maximum login session age, in hours. Default value: 24.

app.HostStatusUpdateTimeout

Sets the interval for collecting and storing script-based node statistics from consoles in minutes. By default, the parameter is not set; the component’s built-in behavior applies.

app.Clock.SystemAndGPSOffset

The offset between the Unix epoch and the GPS epoch in seconds. Default value: 315964800.

app.Clock.GPSAndUTCOffset

The current offset between GPS and UTC time, accounting for leap seconds. Default value: 18.

app.System.SNMP.Trap.Resend.Active.Period

[SNMP] When built with SNMP support, sets the resend interval for active alarm traps in milliseconds. By default, the parameter is not set; the component’s built-in behavior applies.

app.System.SNMP.Trap.Resend.Cleared.Period

[SNMP] When built with SNMP support, sets the resend interval for cleared alarm traps, in milliseconds. By default, the parameter is not set; the component’s built-in behavior applies.

app.System.SNMP.Trap.Resend.Cleared.Count

[SNMP] When built with SNMP support, sets the number of additional sends for each cleared alarm trap. By default, the parameter is not set; the component’s built-in behavior applies.

app.GRPC.Deadline

The deadline for gRPC requests, for example between the dispatcher and the console, in seconds. Default value: 10.

app.GRPC.Console.ReconnectBackoff.Init

The initial backoff for console gRPC reconnection in milliseconds. Default: 200.

app.GRPC.Console.ReconnectBackoff.Min

The minimum backoff for console gRPC reconnection in milliseconds. Default: 200.

app.GRPC.Console.ReconnectBackoff.Max

The maximum backoff for console gRPC reconnection in milliseconds. Default: 3000.

app.Probe.Update.Period

The automatic Probe update interval in seconds. Default value: 10.

app.GRPC.SafeRequest.Enabled

Checks the gRPC connection between the dispatcher and the console before sending a request. Default value: 1 (mode enabled); 0 disables it.

app.GRPC.SafeRequest.Timeout

The time given to the preliminary gRPC connection check in milliseconds. Default value: 500.

app.NetworkWatcher

Monitors changes to network interfaces. Default value: 1 (mode enabled); 0 disables it.

app.NetworkWatcher.ResetAttemptsTimeout

The interval between attempts to reconnect affected listeners and senders after network issues, in milliseconds. Default value: 2000.

app.Sandbox.IdleTimeout

The idle time of the cwNativeSandbox remote configuration process before termination, in minutes. Default value: 60.

app.RemoteServicesController.Timeout

The lifetime of the search for remote services controller after the last request, in seconds. Default value: 30.

app.RemoteTask.Timeout

The retention time of an unused timeout remote task in the controller, in seconds. Default value: 60.

app.RemoteServicesController.ON

Enables the remote services management controller. Default value: 1 (mode enabled); 0 disables it.

app.RSC.LegacyPerformance

Reads and publishes legacy server performance info in cluster announcements. Default value: 0 (mode disabled); 1 enables it.

app.AnnouncesListener.RetryTimeout

The no-data time for multicast announcements before the listener rejoins the group, in seconds. Default value: 20.

app.ActivateLikeConsole

Allows activating the local dispatcher as a console via the Local Service menu. Default value: 0 (mode disabled); 1 enables it.

app.Log.SetParameters

Logs every read and change of every filter parameter. By default, the parameter is not set (mode disabled); 1 enables it, 0 disables it.

app.Log.Local.MaxSize

The maximum size of the local log file, after which a new file is created. Default value: 2 GB.

app.Log.Shared.MaxSize

The maximum size of the shared log file, after which a new file is created. Default value: 100 KB.

app.UserRightsPolicy.Optional

Allows user rights to be enabled and disabled in the configuration if the license permits an optional policy. Default value: 0 (mode disabled); 1 enables it.

app.Server.Redundancy.Host.Alive.Action

Selects the action after the primary node recovers. Default value: 0 (stops the recovered primary node); 1 makes it redundant.

app.Channel.Events.Check.Period

The interval at which the event system checks parameter values in milliseconds; the minimum value is 100. Default value: 1000.

app.SocketListener.AvailableIntefacesCheck.Timeout

The timeout for checking available network interfaces in milliseconds. Default value: 20000.

app.UI.hideInternalConnection

Prevents internal gRPC addresses from being modified in the user interface. Default value: 1 (mode enabled); 0 disables it.

app.GraphElementEvent.Log.Filter

Sets a comma-separated list of GraphElementEvent names to be logged. Default value: parameter not set, and all types are logged; a non-empty value restricts logging to the listed types.

app.Events2.HistoryCapacity

Limits the number of version 2 event history records in memory. Default value: 300 records; 0 disables history.

app.E2.DefaultAudioAlert

The default audio file for version 2 event system alerts. By default, the parameter is not set; the component’s built-in behavior applies.

app.TaskScheduler.MaximumNumThreads

The maximum number of working streams the task scheduler can create. Default value: 1000 streams.

app.TaskScheduler.OptimalNumThreads

The preferred number of working streams maintained by the task scheduler. Default value: 8 streams.

app.TaskScheduler.DefaultOvertimeTimeout

The default allowable overtime for scheduled tasks in milliseconds. Default value: 200 milliseconds.

app.Task.NetworkManager.DefaultOvertimeTimeout

The default allowable overtime for network manager tasks in milliseconds. Default value: 2000.

app.GRPC.Dispatcher.MaxThreads

Limits the number of streams for the dispatcher gRPC server. Default value: 0 (no explicit limit); a positive value sets the maximum number of streams.

app.GRPC.Probe.MessageSize.Maximum

The maximum gRPC message size for Probe in megabytes. Default value: 200.

app.GRPC.Console.MessageSize.Maximum

The maximum gRPC message size for the console in megabytes. Default value: 200.

app.GRPC.Dispatcher.MessageSize.Maximum

The maximum gRPC message size for the dispatcher in megabytes. Default value: 200.

app.GRPC.Console.WaitForConnected

The time to wait for the gRPC connection to the console to become ready in seconds. Default value: 20.

app.Console.Stdout.Silent

Suppresses the console process output to standard output. Default value: 1 (mode enabled); 0 disables it.

app.Channel.Graph.Build.RTMPSource.FindPins.Timeout

The timeout for finding RTMP Source pins during graph building in milliseconds. Default value: 10000.

app.EnableIPv6Interfaces

Allows network source and sink filters to use IPv6 interfaces. Default value: 0 (mode disabled); 1 enables it.

_images/Options_en.png

Setting Up Configurations

A configuration is used to specify settings of encoding consoles (tasks), including reactions on certain events. The default configuration is called Common.

You can choose and(or) set up the required configuration on the Service Settings ➝ Configurations page. Select a configuration from the drop-down list to the right and above, edit the settings if necessary, and click Apply. The current configuration can be downloaded by clicking DownloadIcon. To upload a configuration, use UploadIcon. For deletion, click TrashIcon.

You can create a custom configuration by clicking PlusIcon Add next to the drop-down list. Enter the configuration name and click Ок. If necessary, add multiple configurations and apply them to different tasks.

Each configuration comprises 4 groups of settings: Thresholds, Events, Component Logs, and Options — see below for their description.

Thresholds

Thresholds can be configured via the following parameters:

  • Restart conditions:

    • Restart every N minutes—the console will restart at a set interval in minutes.

    • Restart if CPU usage drops to less than N%—restart the console when the CPU load decreases and remains at this level for the specified time.

    • Restart if RAM usage rises higher than N MB—restart the console if the RAM usage exceeds the set threshold for the specified time.

  • Log statistics every N seconds—task statistics will be additionally recorded to the console log at each specified interval.

  • Actions During Incidents—configures a scenario of automatic actions in case of a failure within the task. You can set the timeout for waiting for a response about a status change in seconds, as well as enable the following checkboxes:

    • Timeout for status change response — time period in seconds: if this runs out, the failure will be signalled.

    • Unload a schema when the console repeatedly restarts—enables schema unload in case task restarts multiple times.

    • Try to change a task state during—after enabling, you can set the number of attempts during which the system will try to change the task state; 0 means an unlimited number of attempts.

    • Unload a schema when a task connection is lost after—after enabling, you can specify the time in seconds, upon reaching which the task schema will be unloaded.

_images/Thresholds_en.png

Events

See the Events System section.

Component Logs

This table contains settings for configuring event-based logging related to a specific Elecard CodecWorks component.

To add a row, click on PlusIcon in the top-left part of the table, and then in each column specify the following:

  • Component — Elecard CodecWorks component.

  • Logging level — contains logging levels; the levels are cumulative, i.e., the lowest level trace includes all previous logging levels. It is recommended to use the info level, which is set by default.

To delete a row, click on the deleteButton button.

_images/ComponentLog_en.png

Options

See the Setting Up Options section.

Events System

The CodecWorks Mux events system notifies users about changes in the task or input stream state and reacts to said changes.

A set of recommended events is pre-configured in the system. You can select one of them or create an event from scratch, if needed.

How the Events System Works

The system lets you work with objects of different levels: you can track the state of the entire encoding schema, schema component, component parameter, or parameter pin. The user chooses an event, sets a target object for monitoring and specifies conditions that the object state analysis will be based on. The system receives data from the target object, performs an analysis based on the specified conditions, and determines the current state of the object.

There are three state types:

  • Good — target object operates normally.

  • Bad — target object is facing irregularities.

  • Signal — a call from the target object that is made every time a certain event, such as a log write error, occurs.

If the object state changes, the system notifies the user. Additionally, the user can set an action the system will perform in response to the state change, e.g., create a log record.

Events Page

In order to create or configure an event, first access the Events page. To access it, start off at the CodecWorks Mux home page, then in the top-right corner click Settings ➝ Service Settings. To the left, click on Thresholds, then open the Events tab.

To the right will be the area for altering the event configurations. For example, you can specify the event’s name in the Event display name field. In the Error level drop-down list, choose the event’s severity level. Available severity levels include Fatal, Major, Error, Warning, Info, Unknown. In the Mode drop-down list, choose the configuration alteration mode:

  • Basic lets you browse and configure Conditions for determining the target object state, but you cannot configure the condition type.

  • Advanced lets you browse and configure conditions as well as specify additional Options and Actions that the system would use to react to a changed state.

  • Expert lets you specify and change conditions, options, actions, and Target Objects.

Options

In the Options section, you can set the following:

  • Use only for active stream enables event monitoring only in the active stream, in tasks with a redundant source present.

  • Duration sets the time period during which a specified condition should or shouldn’t be met in order to let the system register the corresponding state.

  • Reset events after sets the period after which the event will be reverted to its initial state.

  • No check period sets the period after the schema is run, during which no event monitoring is done.

Actions

In the Actions section, you can set system reactions to states. The list of actions is presented as a table. The table rows include the following drop-down lists:

  • State lets you select a state that would trigger an action.

  • Action lets you select an action.

  • Mark lets you select a schema type: any or with/without redundancy.

To add a row, click PlusIcon in the right part of the table header. To delete a row, click TrashIcon.

Users can set the following actions:

  • Visual alert/Enable sound notification

  • Record input stream

  • Record log

  • Run/stop stream

  • Start Python script

  • Send SNMP

  • Restart console

  • Switch to redundant source

  • Rebuild task

  • Create input buffer dump

  • Create process dump

Some actions require you to provide extra data. With this in view, the table makes it possible to add extra fields:

  • Name lets you specify the name of an argument for passing extra data.

  • Value lets you set data value.

To add new fields, click PlusIcon in the row you need.

The actions that require extra data include:

  • Send SNMP: here you have to set snmp as the name and one of the trap types mentioned below as the value. Note that the type depends on the specified state.

    State

    Value

    Good/Bad

    .. to be changed

    Signal

    .. to be changed
  • Start Python script: it is necessary to specify a path to the script. Set path in the Name field and the path itself—such as D:\Scripts\python_script.en—in the Value field. If you need to pass arguments to the script, add new fields, set args as the name then set the argument values.

Target Object

In the Target object section, users can indicate the monitored target object. The following objects are available:

  • Schema—the entire encoding schema (graph) will be monitored.

  • Filter—the component state will be monitored. To add a component for monitoring, enter its name (GUID) in the field under the Filter ID header. You can monitor the state of multiple components simultaneously as part of the same event. In order to insert fields for adding extra components, click PlusIcon next to the header.

  • Parameter lets you monitor the state of a component parameter or a component pin. To set monitoring up, specify the component name in the Filter ID field, then the parameter name in the Parameter ID field.

    A schema can include multiple components that are the same. To explicitly distinguish the component with the monitored parameter, you can specify a custom name for the component in the Filter name field. If you have to monitor the parameter pin, tick the Profile parameters checkbox. You can include multiple parameters in monitoring by clicking PlusIcon. To delete a parameter, click TrashIcon.

    For each parameter, it is possible to set a specific condition for monitoring the state of this particular parameter. Open the Conditions list and choose the item you need. Click the editUser icon to collapse or expand the settings for the chosen condition. To learn more about the settings, see Conditions below.

  • Filter is unknown lets you monitor the component parameter state in case the component is unknown or if there are too many of them. Ensure you set the Parameter ID. You can additionally exclude components out of monitoring by specifying their names in the Exclude filters field. To monitor the parameter of a component pin, tick the Profile parameters checkbox.

Conditions

In the Conditions section, the user sets conditions, based on which the system will determine the state of the target monitoring object. Conditions vary based on which object you choose.

  • For the Schema target object, the GST graph callback condition is available: the system checks the code of a message sent by the graph and notifies the user about a change in the graph state. The condition is set by means of three fields. In the State field select the state, then in the Value field set the message code for the selected state, finally in the Description field enter a notification for the user. See the list of codes here. You can create multiple conditions with various messages. To add a new condition, click PlusIcon. To delete a condition, click TrashIcon.

  • For the Filter target object, the Filter callback condition is available: the system checks the code of a message sent by the component and notifies the user about a change in the component state. In the State field select the state, then in the Code field set the message code for the selected state, finally in the Description field enter a notification for the user. To add a new condition, click PlusIcon. To delete a condition, click TrashIcon.

  • For the Parameter and Filter is unknown target objects, three condition types inside a drop-down list are available:

    • Lower and upper thresholds—the user sets the parameter lower and/or upper threshold. The system compares the data received from the object to the thresholds and determines the object state. To set the lower threshold, tick the checkbox near the corresponding field and enter the required value. If needed, do the same for the upper threshold. If you tick the Relative checkbox, then instead of the current parameter value, the difference between the current and previous value will be compared to the threshold values. The Notify via signal checkbox enables notification sending when the event occurs. In the Good description and Bad description fields, the user can specify messages about the target object state that will be displayed in the interface.

    • Boolean expression works similar to Lower and upper thresholds, except that the thresholds are specified via expressions, such as ( {VALUE}>2 AND {VALUE}<100 ) OR {VALUE}=0 instead of fields. The following operators are supported:

      • Logical AND: AND, and, &&

      • Logical OR: OR, or, ||

      • Equality: =, ==

      • Logical NOT: !

    The system will replace the {VALUE} tag with the parameter values, meaning the tag should always be present in the expression.

  • Special—a special condition for monitoring the state of WebDAV URL addresses. The All or nothing checkbox determines how the system would identify the state. With the checkbox ticked, the system would determine the state as Bad in case at least one URL is invalid. With the checkbox unticked, the system would determine the state as Bad in case all URLs are invalid, or as Signal if only some of the URls are invalid. Use the State change description, Good description and Bad description fields to specify the messages for the Signal, Good, and Bad states correspondingly.

Configuring Events

To configure an event, do the following:

  1. Select a required configuration in the Configuration field in the top-right corner of the Events page.

  2. Select a pre-configured event or create your own by clicking PlusIcon Add Event above the events list.

  3. If needed, specify the Event display name and Error level.

  4. Switch over to expert mode by choosing the corresponding option in the Mode drop-down list.

  5. In the Target object section, choose an object for monitoring and configure it.

  6. In the Conditions section, specify conditions that the system would use to monitor the state of the selected object.

  7. Enter the messages that would show up in response to various states.

  8. In the Options section, enable the required monitoring options.

  9. In the Actions section, set how the system would react to states within the specified event.

  10. Check parameter settings. If needed, you can restore the default settings by clicking RevertIcon on top of the events list. If all is set correctly, click Apply in the top-right corner.

  11. Apply the configuration to a schema.

Events Journal

Events journal shows records about events registered in the system, keeps the history of notifications, and creates event-based logs. By default, the events in the journal are divided into two types: current events that are active at the time the journal is browsed, and complete ones. Current events are always on top and are additionally highlighted with color. By relying on the journal, the user can track active events to address them timely, analyze previous events, and browse the notification history.

_images/EventJournalPage_en.png

To open the events journal, start off at the CodecWorks Mux home page, then hover over the Journals tab in the top-right corner and click Events Journal. You can also open the journal by clicking AlarmJournalIcon in any task row. In this case, the journal will display data related to events for this particular task.

You can filter the data in the journal using filters on top. To enable the selected filters, click Apply. To reset, click Clear Filters.

The journal comprises 8 columns:

  • Level shows an event criticality level: Error or Warning.

  • Name shows an event name.

  • Start Time shows when an event started.

  • End Time shows when a completed event ended.

  • Message shows the message set for a certain event state.

  • Task shows the name of a task. Click the name to open the task page (graph).

  • Location pinpoints the path to the target object inside the graph where a certain event took place.

As the amount of data increases, the records are paginated. To browse through the records, use the navigation under the journal.

You can set the number of items to be shown via the Show per page field to the right and above the journal. To update the journal data, click Refresh. To delete data, click Clear history then confirm deletion in the pop-up window. If the journal has no data to provide, the No events to display message will be shown.